The cookie settings on this website are set to 'allow all cookies' to give you the very best experience. Please click Accept Cookies to continue to use the site.

759X030003

SKU:
759X030003
Condition:
New
Availability:
100 Days
Weight:
350.00 KGS
  • GE 759X030003 CURRENT TRANSFORMER TYPE JKW-350 69KV FREE STAND
  • GE 759X030003 CURRENT TRANSFORMER TYPE JKW-350 69KV FREE STAND Super-Bute
  • GE 759X030003 CURRENT TRANSFORMER TYPE JKW-350 69KV FREE STAND
  • GE 759X030003 CURRENT TRANSFORMER TYPE JKW-350 69KV FREE STAND Super-Bute
Ask us about pricing on the JKW-350 range of Current Transformers

Description

GE 759X030003 CURRENT TRANSFORMER TYPE JKW-350 69KV FREE STAND - SUPERBUTE

RATIO                                             800/1,600:5

IEEE METERING                              0.3/B1.8

IEEE RELAY ACCURACY CLASS       T200/T400

THERMAL RATING FACTOR             2.0/1.33

New - These products are brand new in box, sealed where applicable. Units are covered by original equipment manufacturer (OEM) warranty as applicable.

Model JKW-350 SUPERBUTETM

Outdoor Current Transformer 69 kV, 60 Hz, 350 kV BIL

Application

Designed for outdoor service; suitable for operating meters, relays, and control devices. Rated Station Class with higher burden and extra creep distance. Available in a variety of ratio as outlined in the unit selection table below, with additional designs available upon request.

Features

  •   Weight (Shipping/Unit): 683/593 lbs

  •   Creep Distance: 86.61” [2200 mm]

  •   1-sec Thermal Limit: 75x normal

  •   2 cycle Mechanical Limit: 170x rated (low ratio)

  •   2 cycle Mechanical Limit: 85x rated (high ratio)

  •   Insulation: HY-BUTE 60TM Butyl Rubber

  •   Insulation Class: 350 kV BIL, Outdoor

  •   Design Standard: IEEE C57.13

Tough & Resilient Butyl Rubber Shell

First introduced in 1955, HY-BUTE 60TM is GE’s unique butyl rubber formula. This material is hydrophobic, non-arc tracking, resistant to heat, chemicals, ozone and ultraviolet and is an elastic rubber which does not easily chip or crack. Use of HY-BUTE 60 enhances safety by increasing the likelihood of a passive, contained failure mode.

Accurate & Reliable Primary Design

Symmetrical distribution of winding turns within the CT head shell minimizes leakage flux for improved accuracy and thermal ratings

Built-in Surge Protection

A unique multi-gap primary on CT’s 600 amps and below is designed to clear dangerous overvoltage and fault conditions within 1⁄2 cycle

High Overcurrent Capability

The robust primary bar design on CT’s rated above 600 amps has virtually unlimited short-time mechanical current withstand

View AllClose

Warranty Information

HTML5 Icon

18 Month Warranty
View AllClose